Board-certified dermatologist markKAHF mark (Korea Accreditation Program for Hospitals Serving Foreign Patients)Led by a board-certified dermatologist
Personal diagnosis · Accountable care
Ministry of Health and Welfare
KAHF-accredited hospital

DM DERMATOLOGY

Equipment

EQUIPMENT

We choose equipment
to match the depth of your concern

DM Dermatology in Apgujeong has 18 devices that use radiofrequency, ultrasound, laser, and light.

A gloved hand placing a white ultrasound handpiece coated with clear gel on a reclining patient's jawline

DM Dermatology Equipment

We choose a device by your skin condition, not by its name

Skin concerns form at different depths. Melasma and blemishes sit in the outer layer of the skin, while red blood vessels lie below it in the dermis. Sagging is related to changes in the dermis and in the fascia layer (SMAS) beneath it. Each device differs in the type of energy, the depth it reaches, and what it targets. That is why the right device depends on the concern.

First, a board-certified dermatologist examines the cause and depth of your concern, and your skin's thickness and sensitivity. Then the device, intensity, and number of sessions are chosen. Even for the same concern, the right device can differ from person to person.

  • Elasticity · Lifting
  • Scars · Pores · Texture
  • Pigmentation · Skin tone
  • Redness · Blood vessels
  • Acne · Hair removal
  • Skin care

IN NUMBERS

Our equipment in numbers

  • Devices

    18devices

    Devices at
    DM Dermatology

  • Energy

    6

    Radiofrequency · Ultrasound · Laser · Light
    Heat transfer · Water and pressure

  • Depth

    4.5mm

    Deepest focal depth of
    Ulthera and Shurink ultrasound

ENERGY · DEPTH

Each type of energy reaches
a different depth

Lasers and light are absorbed by different targets depending on their wavelength. When a colored target such as melanin (pigment) or hemoglobin in the blood absorbs light, heat forms at that spot. In general, the longer the wavelength, the deeper it goes.

Radiofrequency warms the dermis with the heat created as electric current passes through tissue. Focused ultrasound gathers energy at one point, like a magnifying glass, and creates small heat points at set depths in the skin. The skin care devices (Triple LDM · Aqua Peel · Qrity) are used to cleanse the skin surface and pores and to replenish moisture.

3D illustration of a skin cross-section. Five beams of light come down from above and stop at epidermal pigment, capillaries, hair follicles, the dermis, and the fascia layer
  1. 1

    Epidermal pigment Melanin built up in the outer layer of the skin shows as melasma, freckles, and blemishes. The 532 Laser, Laser Toning (1064nm), and Cell-toning (420~800nm light) target this pigment.

  2. 2

    Capillaries When fine blood vessels in the upper dermis widen, the face looks red. QuadroStar and DermaV target these vessels with wavelengths absorbed by hemoglobin in the blood.

  3. 3

    Hair follicles · Sebaceous glands Clarity targets hair follicles with 755·1064nm lasers absorbed by the dark pigment in hair (hair removal). Capri's 1,450nm laser warms the upper dermis, where the sebaceous glands next to the hair follicles are.

  4. 4

    Dermis The layer where collagen and elastic fibers are found. Heat reaches this layer in different ways: Thermage FLX and XERF use radiofrequency, Accent Prime uses radiofrequency and ultrasound, Potenza uses radiofrequency from needle tips, Fraxel uses fine columns of laser light, and Tixel uses the heat of a heated tip.

  5. 5

    Fascia layer (SMAS) A thin layer that covers the facial muscles. Ulthera and Shurink focus ultrasound at set depths such as 1.5·3.0·4.5mm, and the 4.5mm depth targets the area near this layer.

This illustration is for explanation only. Actual depth varies with the facial area, skin thickness, and device settings.

DM EQUIPMENT

DM Dermatology equipment

We have sorted our 18 devices into six groups by concern. Tap a name to go to that device's description.

LIFTING

Elasticity · Lifting

Devices that deliver heat to the dermis and fascia layer with radiofrequency and focused ultrasound.

  1. Thermage FLX device

    Thermage FLX

    Thermage FLX

    Cools the epidermis while generating heat in the dermis

    It uses radiofrequency energy and mainly targets the dermis. It is mostly used for skin tightening and fine-line concerns.

    • Facial contour · Sagging skin concerns
    • Wrinkle · Fine-line concerns
    • Heat delivered to the dermis

    See Thermage FLX

  2. XERF device

    XERF

    XERF

    Two frequencies that deliver heat energy deep into the skin

    A non-invasive lifting treatment that uses radiofrequency to deliver energy to deep layers of the skin and stimulate collagen production. It aims to support collagen production in the skin with radiofrequency heat energy. How much changes, and when, varies from person to person.

    • Fine-line concerns
    • Pore · Skin texture concerns
    • Heat delivered to the dermis

    See XERF

  3. Accent Prime device

    Accent Prime

    Accent Prime

    A contour and elasticity device that combines radiofrequency and ultrasound

    Accent Prime is a device that applies the Tune treatment technique. It uses 40.68MHz radiofrequency and ultrasound for elasticity and contour concerns of the body and face.

    • Natural-looking lifting
    • For both face and body
    • Elasticity · Wrinkle concerns

    See Tune Face

  4. Ulthera device

    Ulthera

    Ulthera

    An elasticity and wrinkle device that focuses ultrasound on one point

    Just as a magnifying glass focuses sunlight on one spot to burn paper, this device focuses ultrasound on one spot to generate heat.

    • Designed to reduce damage to the epidermis
    • Heat points at set depths in the skin
    • Depth checked with ultrasound imaging

    See Ulthera

  5. Shurink Lifting device

    Shurink

    Shurink Lifting

    A HIFU ultrasound device for lifting and tightening concerns

    Shurink focuses high-intensity focused ultrasound (HIFU) at a depth of 1.4~4.5mm in the skin and delivers heat to the dermis and the fascia layer (SMAS).

    • Natural-looking lifting
    • Short treatment time of 15~20 min
    • Cartridges for each depth

    See Shurink

SCAR · PORE · TEXTURE

Scars · Pores · Texture

Devices that create tiny treatment zones close together in the skin, helping new tissue form around them.

  1. Potenza device

    Potenza

    Potenza

    Radiofrequency from the tips of microneedles

    Potenza places fine microneedles in the dermis and emits radiofrequency from the needle tips. It delivers heat to the dermis while reducing the heat that reaches the epidermis, and it is used for acne scars and pores.

    • Acne scar treatment
    • Pore · Skin tone concerns
    • Skin elasticity concerns

    See Potenza

  2. Fraxel device

    Fraxel

    Fraxel

    A micro-resurfacing laser for scars and pores

    Fraxel is a fractional laser that applies about 2,000 fine laser beams per 1㎠ to create tiny treatment zones in the skin. It is used for acne scars and pores.

    • Scar treatment · Stretch mark treatment
    • Pigmentation · Pore concerns
    • Encourages skin renewal

    See Scar TreatmentSee Pore Care

  3. Tixel device

    Tixel

    Tixel

    A device that delivers heat directly to the skin, aiming to stimulate collagen production

    Using TMA technology, it delivers heat directly to the skin and aims to promote collagen production and remodeling of the papillary dermis. Recovery is relatively short, but redness and swelling may last 3–7 days, and small scabs may last about 1 week.

    • Skin texture · Wrinkle concerns
    • Scar · Pore concerns

    See Tixel

PIGMENT · TONE

Pigmentation · Skin tone

Devices that treat melasma, blemishes, and dull skin tone with lasers and light absorbed by melanin.

  1. Laser Toning device

    Laser Toning

    Laser Toning

    1064nm toning that targets melanin pigment

    A device that applies a Q-switched Nd:YAG laser (1064nm) evenly over the whole face in several passes at low energy. It is used to lighten pigmentation such as melasma, freckles, and blemishes.

    • Brightening care
    • Pigmentation concerns
    • Even passes at low energy

    See One-Day WhiteningSee Vitamin Care

  2. 532 Laser device

    532 Laser

    532 Laser

    A laser for pigment, also used for tattoo removal

    The 532 Laser is mainly used for brightening and pigment treatment. Pigment absorbs it strongly, so it is mainly used to treat freckles, age spots, and blemishes.

    • Targets surface pigment
    • Pigmentation concerns
    • Laser for pigment

    See One-Day Whitening

  3. Cell-toning device

    Cell Toning

    Cell-toning

    Broad-spectrum light for faint blemishes and pigment

    Cell-toning uses broad-spectrum light of 420~800nm for faint blemishes and pigment. Its built-in cooling mode reduces the feeling of heat during treatment.

    • Built-in cooling mode
    • Faint blemish concerns
    • Automatic facial temperature sensor

    See One-Day Whitening

REDNESS · VESSELS

Redness · Blood vessels

Devices that target widened fine blood vessels with wavelengths absorbed by hemoglobin in the blood.

  1. QuadroStar device

    QuadroStar

    QuadroStar

    A facial redness laser that targets widened blood vessels

    A vascular laser that targets dilated, stretched capillaries and is used to reduce redness on the face. It uses low energy, so it tends to have little effect on melanin. Purple spots or bruising may last 1–2 weeks after treatment.

    • Facial redness · Capillary treatment
    • Treatment of various benign growths
    • Vascular laser
  2. DermaV device

    DermaV

    DermaV

    A dual-wavelength laser for redness, pigmentation, and elasticity concerns

    A dual-wavelength long-pulse laser with an intelligent care system and skin cooling technology, which allows precise treatment. It delivers energy over several passes, which can reduce skin damage, and it is designed to help improve pores, skin texture, and elasticity.

    • Redness concerns
    • Skin texture · Skin elasticity
    • Acne mark · Pore concerns

ACNE · HAIR REMOVAL

Acne · Hair removal

A laser that warms the sebaceous glands, and a laser that targets the pigment in hair.

  1. Capri Laser device

    Capri Laser

    Capri Laser

    Acne treatment with combined wavelengths

    Capri Laser is an acne treatment device that combines the wavelengths of a 1,450nm diode laser and a 400nm blue-light laser. It aims to support sebum release and reduce bacteria in the skin.

    • Acne concerns
    • Pore concerns
    • Fine-line · Elasticity concerns

    See Acne Laser

  2. Clarity Laser device

    Clarity Laser

    Clarity Laser

    A hair removal laser that targets the dark pigment in hair

    Clarity is a hair removal device with 755nm and 1064nm lasers that are absorbed by the dark pigment (melanin) in hair. It targets the follicles where hair grows. For dark or tanned skin, the wavelength and intensity are adjusted for the treatment.

    • Two wavelengths: 755·1064nm
    • Targets hair follicles
    • Hair Removal

    See Hair Removal

SKIN CARE

Skin care

Skin care devices that cleanse the skin and replenish moisture with ultrasound, solutions and pressure, or fine water jets.

  1. Triple LDM device

    LDM Triple 19

    Triple LDM

    Care ultrasound that switches between several frequencies

    A skin care device that delivers ultrasound to the skin, switching between several frequencies at short intervals. It does not make holes in the skin, so recovery is usually less of a burden. It is used for hydration care and calming care.

    • Breakout concerns
    • Elasticity care
    • Moisturizing · Calming care

    See Triple LDM

  2. Aqua Peel device

    Aqua Peel

    Aqua Peel

    Clears out pore impurities / Supplies moisture and nutrients

    Aqua Peel is a skin care device that uses 3-step solutions and pressure to draw impurities out of pores and supply moisture and nutrients to the skin. It is relatively gentle, but sensitive skin may turn red for a short time.

    • Clears out pore impurities
    • Dead skin · Skin texture care
    • Moisture · Nutrient supply

    See Aqua Peel Care

  3. Qrity device

    Qrity

    Qrity

    A water-jet cleansing device for breakout, sebum, and pore concerns

    A skin care device that sprays water jets smaller than pores onto the skin and draws them back in. It washes out sebum and impurities in the pores and supplies moisture to the skin.

    • Fine water jets
    • Pore cleansing
    • Moisture supply

    See Premium Qrity

One device may be used for several concerns. DermaV is also used for pigmentation and hair removal, the 532 Laser for red blood vessels, and Capri for acne scars. The groups follow the treatments DM Dermatology links to each device.

DM DermatologyEquipmentPersonal
Skin Device
A woman with clear skin smiling at the camera in a bright room with sky-blue walls
EquipmentLight · RF
Ultrasound

RECOMMEND

An equipment consultation is recommended if

  • You have several concerns, such as melasma, blemishes, redness, or sagging, and find it hard to decide where to start
  • Several devices are used for the same concern, and you want to understand the differences before choosing
  • You have had redness or hyperpigmentation that lasted a long time after a past device treatment
  • You have an important event and want to know the recovery time in advance to choose a treatment date
  • You are pregnant, have an implanted device such as a pacemaker, or take medication, and want to check whether treatment is possible

PROCESS

How device
treatments work

Whatever the device, the steps from the exam to aftercare guidance are the same.

  1. A patient's face in a round skin analysis device while a gloved hand checks the captured images on a tablet

    step 01

    Skin diagnosis · Consultation

    A board-certified dermatologist checks the skin thickness, the depth of pigment and blood vessels, and the sensitivity of the area of concern. We also ask about your medications, pregnancy, implanted medical devices, and past treatments.

  2. A gloved fingertip adjusting the touch screen of a white skin treatment device

    step 02

    Choosing the device and plan

    We choose a device suited to your concern and skin condition, and set the intensity, number of sessions, and interval. When several devices are combined, we also set the order and spacing.

  3. Near the cheek of a reclining patient in protective eyewear, the tip of a white handpiece in a gloved hand glows blue and faintly lights the cheek

    step 03

    Treatment

    Makeup and sebum are removed by cleansing. Numbing cream is applied if needed, and laser and light treatments are done while you wear protective eyewear.

  4. A staff member placing a cool soothing pad on a reclining patient's face

    step 04

    Soothing and aftercare guidance

    After treatment, we calm the heat and redness. You go home after we explain sun protection and when you can start cleansing and wearing makeup again.

INFORMATION

Treatment info to know before a device treatment

Time and recovery differ for each device group. Read across the row that includes your device.

Procedure timeNumbingRecoveryMakeupIntervalSessions
Elasticity · LiftingThermage FLX · XERF · Accent Prime · Ulthera · Shurink30–90 minNumbing cream 30–60 minRedness for a few hoursSwelling for a few daysSame day6–12 months1 sessionWe then check your progress
Scars · Pores · TexturePotenza · Fraxel · Tixel20–40 minNumbing cream 30–60 minRedness and swelling 3–7 daysSmall scabs for about 1 weekLight makeup from the next dayDo not pick off scabs4 weeks or more3–5 sessions
Pigmentation · Skin toneLaser Toning · 532 Laser · Cell-toning10–30 minUsually noneRedness for a few hours532 spot treatment: small scabs for about 1 weekSame dayToning: 1–2 weeksToning: about 10 sessions
Redness · Blood vesselsQuadroStar · DermaVUnder 30 minUsually noneNumbing cream if you are sensitiveRedness 1–2 weeksPurple spots or bruising, also 1–2 weeksSame day or next day3–4 weeks1–3 sessions
AcneCapri10–30 minNumbing cream 30–60 minRedness and warmth for a few hours to 1 dayFrom the next day3–4 weeks3–4 sessions
Hair removalClarity5–20 minDepending on the areaUsually noneRedness and swelling for a few hours to 1 daySame day4–6 weeks2–6 sessions
Skin careTriple LDM · Aqua Peel · Qrity20–40 minNoneRedness for a few hoursSame day1–2 weeks3–6 sessionsTriple LDM: 5–10 sessions

These are general guidelines for each device type. They vary from person to person with the device, intensity, area, and skin condition. DM Dermatology sets your treatment schedule after an examination.

Caution

Precautions
after device treatment

Until the redness and warmth settle, limit heat, UV exposure, and irritation.

  1. 01
    Sun protection

    Apply sunscreen of SPF 30 or higher 15 min before going out, and reapply every 2 hours. For at least 4 weeks, limit long outdoor activities at midday, and wear a hat or use a sunbrella.

  2. 02
    Heat · Sauna · Exercise

    For the 2–3 days while redness and warmth remain, avoid saunas, jjimjilbang (Korean bathhouses), hot baths, and exercise that makes you sweat a lot. After Fraxel, Potenza, or Tixel, avoid them for 1 week.

  3. 03
    Cleansing

    On the day of treatment, wash gently with lukewarm water and do not rub. After Fraxel, Potenza, or Tixel, use a mild cleanser from the next day.

  4. 04
    Exfoliation · Retinol

    For 1 week, do not use scrubs, peeling products, retinol, or exfoliating ingredients such as AHA and BHA. Let scabs and flaking skin fall off on their own.

  5. 05
    Moisturizing

    Apply a mild, fragrance-free moisturizer 2–3 times a day. Reapply more often if your skin feels dry or tight.

  6. 06
    Contact us about unusual symptoms

    If you have blisters, oozing, pain or redness that keeps getting worse, skin that turns white, or thick dark scabs, contact the clinic right away.

Side effects to know
  • Common reactions are redness, warmth, swelling, and stinging. After toning and skin care devices, they usually settle within a few hours. After Fraxel, Potenza, or Tixel, they usually settle within 3–7 days.
  • After Fraxel, Potenza, Tixel, or spot treatment with the 532 Laser, small scabs or flaking may form and last about 1 week. Picking them off can leave hyperpigmentation or scars.
  • Hyperpigmentation (darkening of the skin) may occur after treatment. It is more likely if you have darker skin, have recently tanned, or are exposed to UV light after treatment. Rarely, many toning sessions at short intervals can cause patchy loss of color.
  • After a vascular laser, purple spots or bruising may appear and last 1–2 weeks.
  • After focused ultrasound such as Ulthera or Shurink, tenderness when pressed may last a few weeks. Bruising, raised marks, and temporary tingling or numbness may occur. Rarely, facial muscles may become weak for a short time.
  • Rarely, blisters, burns, or scars may occur. After treatment, acne or tiny bumps may appear for a short time, or blisters around the lips (herpes) may come back.
  • We do not treat, or we postpone treatment, in these cases: if you are pregnant, if the treatment area has an infection, a wound, or active herpes, or if you have recently become heavily tanned.
  • If you have an implanted electronic device such as a pacemaker or defibrillator, we do not use monopolar radiofrequency devices such as Thermage FLX. Other devices also need to be checked, so please be sure to tell us in advance.
  • Please be sure to tell us during your consultation if: you take medication that makes you sensitive to light, such as some antibiotics; you take or have recently taken isotretinoin (an acne medication); you tend to form large scars, such as keloids; you are breastfeeding; you have fillers, threads, or metal implants in the treatment area; you have tattoos, including eyebrow or eyeliner tattoos; or you have had hyperpigmentation after a past treatment.

※ Treatment results, recovery time, and the degree of side effects vary from person to person.

Dr. Shin Young-ik, Medical Director, board-certified dermatologist

DM DOCTOR

We look at your skin first,
then choose the right device

At DM Dermatology, patients are seen by our medical director, a board-certified dermatologist. We first find out which layer of the skin your concern comes from, then decide with you whether a device is needed and which one suits you.

Dr. Shin Young-ik Medical Director · Board-Certified Dermatologist

  • M.S., Hanyang University College of Medicine
  • Adjunct Professor, Hanyang University
  • Full Member, Korean Dermatological Association
  • Clinical Fellowship in Dermatology, Jefferson Medical College (Thomas Jefferson University), USA
Meet our doctor

FAQ

01Is a dermatology clinic with more devices better?

Having many devices means there are more ways of working to choose from. Results depend less on the number of devices than on an accurate diagnosis, the choice of device, and adjustment of intensity. At DM Dermatology, a board-certified dermatologist examines you, then chooses the device that suits your concern.

02What is the difference between Ulthera and Shurink?

Both devices focus ultrasound (HIFU) at set depths in the skin to create small heat points. Ulthera lets the doctor see the layers under the skin on an ultrasound image during treatment. Shurink is made by the Korean company Classys and uses interchangeable cartridges for each depth. Neither device can be called better than the other; we choose based on skin thickness, the degree of sagging, and sensitivity to pain.

03What is the difference between Thermage and XERF?

Both devices deliver heat to the dermis with monopolar radiofrequency. Thermage FLX uses a single frequency of 6.78MHz, while XERF uses two frequencies, 6.78MHz and 2MHz. XERF is designed to combine the two frequencies to choose how deep the heat reaches. We choose the device based on skin thickness and the area of concern.

04How are Laser Toning, the 532 Laser, and Cell-toning different?

Laser Toning applies a 1064nm laser evenly over the whole face at low energy. The 532 Laser has a short wavelength and is used to target freckles and blemishes in the shallow layers of the skin, spot by spot. Cell-toning uses broad-spectrum light of 420~800nm. Depending on the type and depth of the pigment, one is used alone or they are combined.

05Do device treatments hurt a lot?

Each device feels different. Toning and skin care devices feel like a slight sting or warmth, so they are usually done without numbing. Fraxel, Potenza, Tixel, and lifting devices are often used after numbing cream has been on for 30–60 min. If it hurts during treatment, tell us right away. We will adjust the intensity.

06Can I have treatments with several devices on the same day?

If you have several concerns, two or more devices are sometimes used on the same day. However, when heat overlaps in the skin, the risk of redness and hyperpigmentation can rise, so we adjust the order and intensity. Whether to combine them on the same day or space them out is decided after an examination.

07When can I wear makeup after a device treatment?

After toning, skin care devices, and radiofrequency or ultrasound lifting, you can usually wear makeup the same day. After treatments that leave small scabs, such as Fraxel, Potenza, and Tixel, light makeup from the next day is common. Do not rub areas with scabs.

08What equipment does DM Dermatology in Apgujeong have?

DM Dermatology, near Apgujeong Station Exit 5, has 18 devices. For lifting: Thermage FLX, XERF, Accent Prime, Ulthera, and Shurink. For scars and pores: Potenza, Fraxel, and Tixel. For pigmentation: Laser Toning, the 532 Laser, and Cell-toning. For redness: QuadroStar and DermaV. For acne and hair removal: Capri and Clarity. For skin care: Triple LDM, Aqua Peel, and Qrity.

CONSULTATION

Consultation comes first

Before any treatment is chosen, a board-certified dermatologist checks your skin in person.

DM Dermatology, 4F, 579-1 Sinsa-dong, Gangnam-gu, Seoul

From Apgujeong Station (Line 3) Exit 5, walk straight for 50 m. 4th floor of the A Twosome Place building

Weekdays
am 10:00 - pm 07:00
Saturday
am 10:00 - pm 04:30
Lunch break
pm 01:00 - pm 02:00
Sun & holidays
By appointment only
  • Subway

    3Apgujeong StationExit 5

    Walk straight for 50 m · 2 min on foot · 4th floor of the A Twosome Place building

  • Bus

    Apgujeong Station Exit 4 · Exit 32310523429

    Blue bus147 · 148 · 240 · 463 · 343Green bus4211

    Kwanglim Church · Hyundai High School2310323104

    Blue bus143 · 240 · 345 · 472Green bus3011 · 4312 · 4318

  • By car

    Search in your navigation app158 Apgujeong-ro, Gangnam-gu디엠피부과의원

    Use the building’s underground parking · Parking available in the building

WeChat consultation

DM Dermatology WeChat QR code

WeChat ID : dmderma

Scan the QR code in the WeChat app, or search for our ID and add us.